| acceleration_voltage |
Voltage used for the electron acceleration, in kV |
| acquisition |
|
| assembly |
What type of higher order structure your sample forms - if any |
| authors |
List of authors associated with the project |
| beam_convergence |
Refers to how tightly or widely the electron beam is focused onto the sample,... |
| beamshift |
Movement of the beam above the sample for data collection purposes that does ... |
| beamtilt |
Another way to move the beam above the sample for data collection purposes th... |
| beamtiltgroups |
Number of Beamtilt groups present in this dataset - for optimized processing ... |
| binning_camera |
Level of binning on the images applied during data collection |
| budget |
budget |
| buffer |
Name/composition of the (chemical) sample buffer during grid preparation |
| c2_aperture |
C2 aperture size used in data acquisition, in µm |
| calibrated_defocus |
Machine estimated defocus, min and max values in µm |
| calibrated_magnification |
Calculated magnification, no unit |
| chromatic_aberration_corrector |
Specialist device to correct for chromatic aberration of the microscope lense... |
| collection_angle |
Collection angle set, min and max values in mrad |
| concentration |
Concentration of the (supra)molecule in the sample, in mg/ml |
| country |
Country of the institution |
| cryogen |
Cryogen used in cooling the instrument and sample, usually nitrogen |
| cs |
Spherical aberration of the instrument, in mm |
| date_time |
Time and date of the data acquisition |
| description |
The description of the item |
| descriptor_name |
Name defining the descriptor |
| descriptor_thing |
Description of the descriptor |
| descriptors |
List of custom descriptors for user-defined key-value pairs describing how mo... |
| detectors |
|
| dispersion |
Dispersion of an analytical detector, in eV |
| dose_per_movie |
Average dose per image/movie/tilt - given in electrons per square Angstrom |
| electron_source |
Type of electron source used in the microscope, such as FEG |
| email |
email |
| embedding |
Whether the sample was embedded |
| end_date |
end date |
| energy_filter |
Whether an energy filter was used and its specifics |
| exposure_time |
Time of data acquisition per movie/tilt - in s |
| expression_system |
Scientific name of the organism used to produce the molecule of interest |
| family_name |
last name |
| film_material |
Type of material the support film is made of |
| film_support |
Whether a support film was used |
| film_thickness |
Thickness of the support film |
| film_topology |
Topology of the support film |
| frames_per_movie |
Number of frames that on average constitute a full movie, can be a bit hard t... |
| funder |
funding organization/person |
| funder_name |
funding organization/person |
| gainref_flip_rotate |
Whether and how you have to flip or rotate the gainref in order to align with... |
| gene_name |
Name of the gene of interest |
| given_name |
first name |
| grant_name |
name of the grant |
| grants |
List of grants associated with the project |
| grid |
Description of the grid used |
| grids_imaged |
Number of grids imaged for this project - here with qualifier during this dat... |
| height |
The height of a given item - unit depends on item |
| holder |
Speciman holder model |
| holder_cryogen |
Type of cryogen used in the holder - if the holder is cooled seperately |
| humidity |
Environmental humidity just before vitrification, in % |
| illumination |
Mode of illumination used during data collection |
| image_size |
The size of the image in pixels, height and width given |
| images_generated |
Number of images generated total for this data collection - might need a qual... |
| imageshift |
Movement of the Beam below the image in order to shift the image on the detec... |
| imaging |
Mode of imaging used during data collection |
| increment |
Increment between elements of a series |
| instrument |
|
| instrument_type |
Details of a given specialist instrument |
| job_title |
job title |
| ligands |
List of ligands associated with the sample |
| manufacturer |
The name of the manufacturer |
| material |
Material out of which the grid is made |
| maximal |
Maximal value of a given dataset property |
| mesh |
Grid mesh in lines per inch |
| microscope |
Microscope information |
| microscope_software |
Software used for instrument control, |
| minimal |
Minimal value of a given dataset property |
| mode |
Mode of the detector, e |
| model |
The model of the item |
| molecular_class |
Class of the molecule |
| molecular_overall_type |
Description of the overall molecular type, i |
| molecular_type |
Description of the overall molecular type, i |
| molecular_weight |
Molecular weight in Da |
| molecule |
List of molecule associated with the sample |
| name |
The name of the item |
| name_mol |
Name of an individual molecule (often protein) in the sample |
| name_org |
Name of the organization |
| name_sample |
Name of the full sample |
| natural_source |
Scientific name of the natural host organism |
| nominal_defocus |
Target defocus set, min and max values in nm |
| nominal_magnification |
Magnification level as indicated by the instrument, no unit |
| operating_mode |
Operating mode of the microscope, i |
| orcid |
ORCID of the author, a type of unique identifier |
| organizational |
|
| overall_molecule |
Description of the overall molecule |
| person |
person |
| ph |
pH of the sample buffer |
| phaseplate |
Phaseplate is a special optics device that can be used to enhance contrast |
| pixel_size |
Pixel size, in Angstrom |
| present |
Whether the model contains any ligands |
| pretreatment_atmosphere |
Atmospheric conditions in the chamber during pretreatment, i |
| pretreatment_pressure |
Pressure of the chamber during pretreatment, in Pa |
| pretreatment_time |
Length of time of the pretreatment in s |
| pretreatment_type |
Type of pretreatment of the grid, i |
| project_id |
project id |
| reference |
Link to a reference of your ligand, i |
| role |
Role of the author, for example principal investigator |
| sample |
|
| screen_current |
The total electron beam current hitting the viewing screen, in nA |
| sequence |
Full sequence of the sample as in the data, i |
| shadowing |
Whether the sample was shadowed |
| smiles |
Provide a valid SMILES string of your ligand |
| source |
Where the sample was taken from, i |
| specialist_optics |
Any type of special optics, such as a phaseplate |
| specimen |
Description of the specimen |
| spherical_aberration_corrector |
Specialist device to correct for spherical aberration of the microscope lense... |
| staining |
Whether the sample was stained |
| start_date |
start date |
| taxonomy_id_expression |
Taxonomy ID of the expression system organism |
| taxonomy_id_source |
Taxonomy ID of the natural source organism |
| technique |
Specifies which Acquisition subschema/class is in use |
| telephone |
work phone |
| temperature |
Environmental temperature just before vitrification, in K |
| temperature_range |
Temperature during data collection, in K with min and max values |
| tilt_angle |
The min, max and increment of the tilt angle in a tomography session |
| tilt_axis_angle |
The tilt axis angle of a tomography series |
| type_org |
Type of organization, academic, commercial, governmental, etc |
| unit |
the unit of a given value |
| unitSI |
the SI unit attached to a si value |
| used |
whether a specific instrument was used during data acquisition |
| value |
the value of a field with a unit |
| valueSI |
value of a given field in respect to its SI unit |
| vitrification |
Whether the sample was vitrified |
| vitrification_cryogen |
Which cryogen was used for vitrification |
| width |
The width of a given item - unit depends on item |
| width_energy_filter |
Width of the energy filter used |
| x_max |
maximum x |
| x_min |
minimum x |
| y_max |
maximum y |
| y_min |
minimum y |